INO
CNR
vai_a_storia   vai_a_organizzazione   vai_a_sedi   vai_a_personale   Area Riservata
    English English Version  
 
 

Elemental mapping and microimaging by x-ray capillary optics

  Articoli su Riviste JCR/ISI  (anno 2008)

Autori:  Hampai D., Dabagov S.B., Cappuccio G., Longoni A., Frizzi T., Cibin G., Guglielmotti V., Sala M

Affiliazione Autori:  CNR - Istituto Nazionale di Ottica Applicata, Largo E. Fermi, 6,I-50125 Firenze, Italy; INFN- Laboratori Nazionali di Frascati, Via E. Fermi, 44,I-00040 Frascati (RM), Italy; MINASlab, Dipartimento di Scienze e Tecnologie Chimiche, Universitá di Roma “Tor Vergata”; Russian Academy of Sciences–P.N. Lebedev Physical Institute, Leninsky prospect 53, 119991 Moscow, Russia; Politecnico di Milano, Dip. di Elettronica e Informatica, Via Golgi 40, 20133, Milano, Italy; Diamond Light Source Ltd., Chilton, Didcot OX11 ODE, UK; Dipartimento di Scienze della Terra A. Desio, Universitá di Milano, Italy

Riassunto:  Recently, many experiments have highlighted the advantage of using polycapillary optics for x-ray fluorescence studies. We have developed a special confocal scheme for micro x-ray fluorescence measurements that enables us to obtain not only elemental mapping of the sample but also simultaneously its own x-ray imaging. We have designed the prototype of a compact x-ray spectrometer characterized by a spatial resolution of less than 100 mu m for fluorescence and less than 10 mu m for imaging. A couple of polycapillary lenses in a confocal configuration together with a silicon drift detector allow elemental studies of extended samples (similar to 3 mm) to be performed, while a CCD camera makes it possible to record an image of the same samples with 6 mu m spatial resolution, which is limited only by the pixel size of the camera. By inserting a compound refractive lens between the sample and the CCD camera, we hope to develop an x-ray microscope for more enlarged images of the samples under test. (C) 2008 Optical Society of America

Rivista/Giornale:  OPTICS LETTERS
Volume n.:  33 (23)      Pagine da: 2743  a: 2745
DOI: 10.1364/OL.33.002743

*Impact Factor della Rivista: (2008) 3.772   *Citazioni: 21
data tratti da "WEB OF SCIENCE" (marchio registrato di Thomson Reuters) ed aggiornati a:  19/05/2019

Riferimenti visionabili in IsiWeb of Knowledge: (solo per sottoscrittori)
Per visualizzare la scheda dell'articolo su IsiWeb: Clicca qui
Per visualizzare la scheda delle Citazioni dell'articolo su IsiWeb: Clicca qui

INO © Istituto Nazionale di Ottica - Largo Fermi 6, 50125 Firenze | Tel. 05523081 Fax 0552337755 - P.IVA 02118311006     P.E.C.    Info