INO
CNR
vai_a_storia   vai_a_organizzazione   vai_a_sedi   vai_a_personale   Area Riservata
    English English Version  
 
 

Comb-assisted subkilohertz linewidth quantum cascade laser for high-precision mid-infrared spectroscopy

  Articoli su Riviste JCR/ISI  (anno 2013)

Autori:  Galli I., Siciliani de Cumis M., Cappelli F., Bartalini S., Mazzotti D., Borri S., Montori A., Akikusa N., Yamanishi M., Giusfredi G., Cancio P., De Natale P

Affiliazione Autori:  CNR-INO-Istituto Nazionale di Ottica, Largo E. Fermi 6, 50125 Firenze, FI, Italy; LENS-European Laboratory for Non-Linear Spectroscopy, Via Carrara 1, 50019 Sesto Fiorentino, FI, Italy; CNR-IFN-Istituto di Fotonica e Nanotecnologie, Via Amendola 173, 70126 Bari, BA, Italy; Development Bureau Laser Device RD Group, Hamamatsu Photonics KK, Shizuoka 434-8601, Japan; Central Research Laboratories, Hamamatsu Photonics KK, Shizuoka 434-8601, Japan

Riassunto:  We report on the linewidth narrowing of a room-temperature mid-infrared quantum cascade laser by phase-locking to a difference-frequency-generated radiation referenced to an optical frequency comb synthesizer. A locking bandwidth of 250 kHz, with a residual rms phase-noise of 0.56 rad, has been achieved. The laser linewidth is narrowed by more than 2 orders of magnitude below 1 kHz, and its frequency is stabilized with an absolute traceability of 2 × 10 - 12. This source has allowed the measurement of the absolute frequency of a CO2 molecular transition with an uncertainty of about 1 kHz.(C) 2013 American Institute of Physics

Rivista/Giornale:  APPLIED PHYSICS LETTERS
Volume n.:  102 (12)      Pagine da: 121117  a: 121117
Ulteriori informazioni:  This work was financially supported by Ente Cassa di Risparmio di Firenze, by the Extreme Light Infrastructure (ELI) European project, by the Laserlab-Europe Consortium in the ALADIN project framework, and by the Progetto Operativo Nazionale (PON) PON01_01525 Monitoraggio Innovativo per le Coste e l\'Ambiente Marino (MONICA) funded by Italian Ministry of Education, University and Research (MIUR).
DOI: 10.1063/1.4799284

*Impact Factor della Rivista: (2013) 3.515   *Citazioni: 39
data tratti da "WEB OF SCIENCE" (marchio registrato di Thomson Reuters) ed aggiornati a:  19/05/2019

Riferimenti visionabili in IsiWeb of Knowledge: (solo per sottoscrittori)
Per visualizzare la scheda dell'articolo su IsiWeb: Clicca qui
Per visualizzare la scheda delle Citazioni dell'articolo su IsiWeb: Clicca qui

INO © Istituto Nazionale di Ottica - Largo Fermi 6, 50125 Firenze | Tel. 05523081 Fax 0552337755 - P.IVA 02118311006     P.E.C.    Info