INO
CNR
vai_a_storia   vai_a_organizzazione   vai_a_sedi   vai_a_personale   Area Riservata
    English English Version  
 
 

Characteristic vibrational frequencies of toxic polychlorinated dibenzo-dioxins and -furans

  Articoli su Riviste JCR/ISI  (anno 2014)

Autori:  Patrizi B., Siciliani de Cumis M., Viciani S., D'Amato F., Foggi P

Affiliazione Autori:  LENS, University of Florence, Via Nello Carrara 1, 50019 Sesto Fiorentino (FI), Italy; CNR, Istituto Nazionale di Ottica, Largo Enrico Fermi 6, 50125 Firenze, Italy; Università degli Studi di Perugia, Dipartimento di Chimica, Via Elce di Sotto 8, 06123 Perugia, Italy

Riassunto:  The possibility to monitor in real-time the emission of dioxins produced by incineration of waste or by industrial processes is nowadays a necessity considering the high toxicity of these compounds, their persistence in the environment and their ability to bio-accumulate in the food chain. Recently it has been demonstrated the potentiality of detecting dioxins in carbon tetrachloride via MIR Quantum Cascade Lasers. A fundamental step in real time monitoring of dioxins emission is the possibility to recognize the most toxic congeners within complex mixtures and at low concentrations. Taking into account the lack of spectroscopic data about these very toxic environmental pollutants and the necessity to monitor their emissions we have recorded infrared spectra of 13 of the 17 most toxic congeners of polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzo-furans (PCDFs) dissolved in carbon tetrachloride. In this way we have obtained a small database that we have used to test the ability of a linear regression algorithm to recognize each congener and its relative concentration in complex mixtures of these compounds. (C) 2014 Elsevier B.V. All rights reserved.

Rivista/Giornale:  JOURNAL OF HAZARDOUS MATERIALS
Volume n.:  274      Pagine da: 98  a: 105
Ulteriori informazioni:  The authors gratefully acknowledge the financial support from Regione Toscana, within the frame of POR CreO FESR 2007-2013, Project SIMPAS (Innovative Measurement Systems for the Protection of Environment and Health).
DOI: 10.1016/j.jhazmat.2014.04.004

*Impact Factor della Rivista: (2014) 4.529   *Citazioni: 3
data tratti da "WEB OF SCIENCE" (marchio registrato di Thomson Reuters) ed aggiornati a:  21/07/2019

Riferimenti visionabili in IsiWeb of Knowledge: (solo per sottoscrittori)
Per visualizzare la scheda dell'articolo su IsiWeb: Clicca qui
Per visualizzare la scheda delle Citazioni dell'articolo su IsiWeb: Clicca qui

INO © Istituto Nazionale di Ottica - Largo Fermi 6, 50125 Firenze | Tel. 05523081 Fax 0552337755 - P.IVA 02118311006     P.E.C.    Info