INO
CNR
vai_a_storia   vai_a_organizzazione   vai_a_sedi   vai_a_personale   Area Riservata
    English English Version  
 
 

Clear Microfluidics imaging through flowing blood by digital holography

  Articoli su Riviste JCR/ISI  (anno 2014)

Autori:  Bianco V., Paturzo M., Finizio A., Calabuig A., Javidi B., Ferraro P

Affiliazione Autori:  CNR INO (National Institute of Opticts) Pozzuoli (NA), 80078 Pozzuoli, NA, Italy; ECE Department, University of Connecticut, Storrs, CT 06269 USA

Riassunto:  Achieving a clear vision through turbid fluids is a highly desirable goal in microfluidics In particular, observing par tides dipped inside blood shows fascinating perspectives in all fields of bio-medical research. White-light microscopy cannot provide clear imaging due to the strong scattering of light by red blood cells. Here we solve the problem by Digital Holography microscopy. We show that, in cases where the blood flows along a microfluidic channel at sufficient speed, the hologram acts as a selective filter. This occurs due to the Doppler frequency shift experienced by the photons hitting the red blood cells, discarding the unwanted scattering. In cases where the blood flow is not quick enough to take advantage of the Doppler shift, multiple holograms can be processed to produce a clear image of the object. We show that the correlation coefficients between multiple acquisitions at different fluid speeds can be adopted to study the visibility of the fringes due to the moving colloidal particles in the medium. Hence, we estimate the threshold velocity required to completely discard all the scattered photons. In this way the object is seen as dipped in a transparent liquid thus completely eliminating the negative effect of turbidity on the imaging.

Rivista/Giornale:  IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS
Volume n.:  20 (3)      Pagine da: 6801507  a: 6801507
Ulteriori informazioni:  This work was supported by Progetto Bandiera \"La Fabbrica del Futuro\" in the framework of the funded project \"Plastic lab-on-chips for the optical manipulation of single cells\" (PLUS).
DOI: 10.1109/JSTQE.2013.2286075

*Impact Factor della Rivista: (2014) 2.828   *Citazioni: 36
data tratti da "WEB OF SCIENCE" (marchio registrato di Thomson Reuters) ed aggiornati a:  19/05/2019

Riferimenti visionabili in IsiWeb of Knowledge: (solo per sottoscrittori)
Per visualizzare la scheda dell'articolo su IsiWeb: Clicca qui
Per visualizzare la scheda delle Citazioni dell'articolo su IsiWeb: Clicca qui

INO © Istituto Nazionale di Ottica - Largo Fermi 6, 50125 Firenze | Tel. 05523081 Fax 0552337755 - P.IVA 02118311006     P.E.C.    Info