INO
CNR
vai_a_storia   vai_a_organizzazione   vai_a_sedi   vai_a_personale   Area Riservata
    English English Version  
 
 

Active accumulation of very diluted biomolecules by nano-dispensing for easy detection below the femtomolar range

  Articoli su Riviste JCR/ISI  (anno 2014)

Autori:  Grilli S., Miccio L., Gennari O., Coppola S., Vespini V., Battista L., Orlando P., Ferraro P

Affiliazione Autori:  National Institute of Optics - CNR, via Campi Flegrei 34, Pozzuoli (NA) I-80078, Italy; Institute of Protein Biochemistry - CNR, via Campi Flegrei 34, Pozzuoli (NA) I-80078, Italy; CNR-INO and CNR "E. Caianiello", via Campi Flegrei 34, Pozzuoli (NA) I-80078, Italy

Riassunto:  Highly sensitive detection of biomolecules is of paramount interest in many fields including biomedicine, safety and eco-pollution. Conventional analyses use well-established techniques with detection limits similar to 1 pM. Here we propose a pyro-concentrator able to accumulate biomolecules directly onto a conventional binding surface. The operation principle is relatively simple but very effective. Tiny droplets are drawn pyro-electro-dynamically and released onto a specific site, thus increasing the sensitivity. The reliability of the technique is demonstrated in case of labelled oligonucleotides diluted serially. The results show the possibility to detect very diluted oligonucleotides, down to a few hundreds of attomoles. Excellent results are shown also in case of a sample of clinical interest, the gliadin, where a 60-fold improved detection limit is reached, compared with standard ELISA. This method could open the way to a mass-based technology for sensing molecules at very low concentrations, in environmental as well as in diagnostics applications.

Rivista/Giornale:  NATURE COMMUNICATIONS
Volume n.:  5      Pagine da: 5314-1  a: 5314-6
Ulteriori informazioni:  We acknowledge the Italian Ministry of Research for financial support under \'Futuro in Ricerca 2010\' Programme (Protocol RBFR10FKZH) and under the \'Progetto Operativo Nazionale\' AquaSystem (Protocol 1719). We thank Dr. Sabato D\'Auria from CNR-IBP for the fruitful discussions.
DOI: 10.1038/ncomms6314

*Impact Factor della Rivista: (2014) 11.470   *Citazioni: 17
data tratti da "WEB OF SCIENCE" (marchio registrato di Thomson Reuters) ed aggiornati a:  19/05/2019

Riferimenti visionabili in IsiWeb of Knowledge: (solo per sottoscrittori)
Per visualizzare la scheda dell'articolo su IsiWeb: Clicca qui
Per visualizzare la scheda delle Citazioni dell'articolo su IsiWeb: Clicca qui

INO © Istituto Nazionale di Ottica - Largo Fermi 6, 50125 Firenze | Tel. 05523081 Fax 0552337755 - P.IVA 02118311006     P.E.C.    Info