INO
CNR
vai_a_storia   vai_a_organizzazione   vai_a_sedi   vai_a_personale   Area Riservata
    English English Version  
 
 

Clearing of fixed tissue: A review from a microscopist

  Articoli su Riviste JCR/ISI  (anno 2016)

Autori:  Silvestri L., Costantini I., Sacconi L., Pavone F

Affiliazione Autori:  National Institute of Optics, National Research Council, Via Nello Carrara 1, Sesto Fiorentino, Florence, 50019, Italy; European Laboratory for Non-linear Spectroscopy, Via Nello Carrara 1, Sesto Fiorentino, Florence, 50019, Italy; University of Florence, Department of Physics and Astronomy, Via Sansone 1, Sesto Fiorentino, Florence, 50019, Italy

Riassunto:  Chemical clearing of fixed tissues is becoming a key instrument for the three-dimensional reconstruction of macroscopic tissue portions, including entire organs. Indeed, the growing interest in this field has both triggered and been stimulated by recent advances in high-throughput microscopy and data analysis methods, which allowed imaging and management of large samples. The strong entanglement between clearing methods and imaging technology is often overlooked, as typical classification of the former is based only on the chemicals used. Here, we review the recent literature in the field, proposing a taxonomy of clearing techniques based on their mating with the major high-throughput microscopies. We hope that this application-oriented classification can help researchers to find the protocol best suited to their experiment among the many present in the literature. (C) 2016 Society of Photo-Optical Instrumentation Engineers (SPIE)

Rivista/Giornale:  JOURNAL OF BIOMEDICAL OPTICS
Volume n.:  21      Pagine da: 081205-1  a: 081205-8
Ulteriori informazioni:  The authors received funding support from the European Union Seventh Framework Program (FP7/2007-2013) under Grant No. 604102 (Human Brain Project) and Grant No. 284464 (LASERLAB-EUROPE). They have also been supported by the Italian Ministry for Education, University, and Research in the framework of the Flagship Project NanoMAX, and by \"Ente Cassa di Risparmio di Firenze\" (private foundation).
DOI: 10.1117/1.JBO.21.8.081205

*Impact Factor della Rivista: (2016) 2.530   *Citazioni: 30
data tratti da "WEB OF SCIENCE" (marchio registrato di Thomson Reuters) ed aggiornati a:  19/05/2019

Riferimenti visionabili in IsiWeb of Knowledge: (solo per sottoscrittori)
Per visualizzare la scheda dell'articolo su IsiWeb: Clicca qui
Per visualizzare la scheda delle Citazioni dell'articolo su IsiWeb: Clicca qui

INO © Istituto Nazionale di Ottica - Largo Fermi 6, 50125 Firenze | Tel. 05523081 Fax 0552337755 - P.IVA 02118311006     P.E.C.    Info