INO
CNR
vai_a_storia   vai_a_organizzazione   vai_a_sedi   vai_a_personale   Area Riservata
    English English Version  
 
 

Evaluation of a 3D diamond detector for medical radiation dosimetry

  Articoli su Riviste JCR/ISI  (anno 2017)

Autori:  Kanxheri K., Servoli L., Oh A., Munoz Sanchez F., Forcolin G.T., Murphy S.A., Aitkenhead A., Moore C.J., Morozzi A., Passeri D., Bellini M., Corsi C., Lagomarsino S., Sciortino S

Affiliazione Autori:  INFN — Sezione di Perugia, Via A. Pascoli 33, Perugia 06123, Italy; INFN — Sezione di Firenze, Via G. Sansone 1, Firenze 50019, Italy; Dipartimento di Fisica, Università degli studi di Perugia, Via Pascoli 33, Perugia 06123, Italy; Dipartimento di Ingegneria, Università degli studi di Perugia, Via G. Duranti 93, Perugia 06131, Italy; Dipartimento di Fisica, Università degli studi di Firenze, Via G. Sansone 1, Firenze 50019, Italy; Physics Department, University of Manchester, Oxford Road, Manchester M13 9PL, U.K.; The Christie NHS Foundation Trust, Wilmslow Road, Manchester M20 4BX, U.K.; Manchester Academic Health Science Centre, Grafton Street, Manchester M13 9NT, U.K.; INO-CNR di Firenze, Largo Enrico Fermi 6, Firenze 50125, Italy; LENS Firenze Via Carrara 1, Firenze 50019, Italy

Riassunto:  Synthetic diamond has several properties that are particularly suited to applications in medical radiation dosimetry. It is tissue equivalent, not toxic and shows a high resistance to radiation damage, low leakage current and stability of response. It is an electrical insulator, robust and realizable in small size; due to these features there are several examples of diamond devices, mainly planar single-crystalline chemical vapor depositation (sCVD) diamond, used for relative dose measurement in photon beams. Thanks to a new emerging technology, diamond devices with 3-dimensional structures are produced by using laser pulses to create graphitic paths in the diamond bulk. The necessary bias voltage to operate such detector decreases considerably while the signal response and radiation resistance increase. In order to evaluate the suitability of this new technology for measuring the dose delivered by radiotherapy beams in oncology a 3D polycrystalline (pCVD) diamond detector designed for single charged particle detection has been tested and the photon beam profile has been studied. The good linearity and high sensitivity to the dose observed in the 3D diamond, opens the way to the possibility of realizing a finely segmented device with the potential for dose distribution measurement in a single exposure for small field dosimetry that nowadays is still extremely challenging.

Rivista/Giornale:  JOURNAL OF INSTRUMENTATION
Volume n.:  12      Pagine da: P01003  a: P01003
Ulteriori informazioni:  This work has been partially supported by \"Fondazione Cassa di Risparmio Perugia - Progetto 3Dose 2016.0107.021\".
DOI: 10.1088/1748-0221/12/01/P01003

*Impact Factor della Rivista: (2017) 1.258   *Citazioni: 2
data tratti da "WEB OF SCIENCE" (marchio registrato di Thomson Reuters) ed aggiornati a:  19/05/2019

Riferimenti visionabili in IsiWeb of Knowledge: (solo per sottoscrittori)
Per visualizzare la scheda dell'articolo su IsiWeb: Clicca qui
Per visualizzare la scheda delle Citazioni dell'articolo su IsiWeb: Clicca qui

INO © Istituto Nazionale di Ottica - Largo Fermi 6, 50125 Firenze | Tel. 05523081 Fax 0552337755 - P.IVA 02118311006     P.E.C.    Info