INO
CNR
vai_a_storia   vai_a_organizzazione   vai_a_sedi   vai_a_personale   Area Riservata
    English English Version  
 
 

Rovibrational fine structure and transition dipole moment of CF3H by frequency-comb-assisted saturated spectroscopy at 8.6μm

  Articoli su Riviste JCR/ISI  (anno 2018)

Autori:  Vicentini E., Gambetta A., Coluccelli N., Fasci E., Castrillo A., Gianfrani L., Di Sarno V., Maddaloni P., Ceausu-Velcescu A., De Natale P., Wang,Y., Fernandez T.T., Laporta P., Galzerano G

Affiliazione Autori:  Dipartimento di Fisica-Politecnico di Milano, Piazza Leonardo da Vinci 32, Milano 20133, Italy; Istituto di Fotonica e Nanotecnologie-CNR, Piazza Leonardo da Vinci 32, Milano 20133, Italy; Dipartimento di Matematica e Fisica, Università degli Studi della Campania “Luigi Vanvitelli”, Viale Lincoln 5, Caserta 81100, Italy; Istituto Nazionale di Ottica - CNR, Via Campi Flegrei 34, Pozzuoli(NA) 80078, Italy e INFN, Istituto Nazionale di Fisica Nucleare, Sez. di Napoli, Complesso Universitario di M.S. Angelo, Via Cintia, Napoli, 80126 Italy; Laboratoire de Mathématiques et Physique, Université de Perpignan, Via Domitia EA 4217, Perpignan F-66860, France; Istituto Nazionale di Ottica - CNR, Largo E. Fermi, 6, Firenze 50125 Italy

Riassunto:  We report on rovibrational fine structure spectroscopy of room-temperature trifluoromethane with a saturated absorption method, using a quantum cascade laser at around 8.6 μm phase-locked to a self-referenced mid-infrared frequency comb synthesizer. The absolute line-center frequencies of 36 lines have been measured by means of the wavelength modulation method with a best fractional uncertainty of ∼3×10−9 in a single acquisitionn a single acquisition scan from 34.7426 to 34.7443 THz. In addition, an extensive investigation of the measured Lamb-dip profiles using both direct pump-probe spectroscopy method and wavelength modulation technique has been performed for two selected lines, rR40(64) and rR36(38), be-longing to the υ5 vibrational band, as a function of either the gas pressure or the pump beam power. This approach allowed the measurement of the main spectroscopic parameters, such as saturation intensity, transition electric dipole moment, as well as self-pressure broadening coefficient. © 2018 Elsevier Ltd. All rights reserved.

Rivista/Giornale:  JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER
Volume n.:  217      Pagine da: 373  a: 379
DOI: 10.1016/j.jqsrt.2018.06.013

   *Citazioni: 1
data tratti da "WEB OF SCIENCE" (marchio registrato di Thomson Reuters) ed aggiornati a:  12/05/2019

Riferimenti visionabili in IsiWeb of Knowledge: (solo per sottoscrittori)
Per visualizzare la scheda dell'articolo su IsiWeb: Clicca qui
Per visualizzare la scheda delle Citazioni dell'articolo su IsiWeb: Clicca qui

INO © Istituto Nazionale di Ottica - Largo Fermi 6, 50125 Firenze | Tel. 05523081 Fax 0552337755 - P.IVA 02118311006     P.E.C.    Info