INO
CNR
vai_a_storia   vai_a_organizzazione   vai_a_sedi   vai_a_personale   Area Riservata
    English English Version  
 
 

Nonlinear Goniometry by Second-Harmonic Generation in AlGaAs Nanoantennas

  Articoli su Riviste JCR/ISI  (anno 2018)

Autori:  Carletti L., Marino G., Ghirardini L., Gili V.F., Rocco D., Favero I., Locatelli A., Zayats A.V., Celebrano M., Finazzi M., Leo G., De Angelis C., Neshev D

Affiliazione Autori:  Univ Brescia, Dept Informat Engn, Via Branze 38, I-25123 Brescia, Italy; INO CNR, Via Branze 38, I-25123 Brescia, Italy; Univ Paris Diderot, CNRS UMR 7162, Mat & Phenomenes Quant, Sorbonne Paris Cite, 10 Rue A Domon & L Duquet, F-75013 Paris, France; Australian Natl Univ, Res Sch Phys & Engn, Nonlinear Phys Ctr, Canberra, ACT 2601, Australia; Kings Coll London, Dept Phys, London WC2R 2LS, England; Politecn Milan, Dept Phys, Piazza Leonardo Da Vinci 32, I-20133 Milan, Italy

Riassunto:  High-permittivity semiconductor nanoresonators have shown great potential for enhanced nonlinear light matter interactions at the nanoscale due to the availability of a rich variety of resonances combined with low optical losses and a strong bulk nonlinearity. Second-harmonic generation in AlGaAs nanoantennas can be extremely efficient and exhibits a complex radiation pattern. However, the complexity of this far-field profile imposes severe constraints on practical applications and detection efficiency. In this work, we demonstrate, both experimentally and numerically, the control over the angular distribution of the second-harmonic radiation pattern from a monolithic AlGaAs-on-AlOx nanodisk by varying the polarization and the angle of incidence of the pump beam. By tuning the angle of incidence of a beam with s-polarized light from 0 to 45 degrees, the detected second-harmonic signal is monotonically increased up to over an order of magnitude due to the strong dependence of the nonlinear radiation pattern on the pump beam properties. Our results demonstrate that precise angular measurements of the pump inclination can be performed with a relative intensity change of the second-harmonic signal up to 0.25 deg(-1) and polarization discrimination, therefore establishing a new technique for background-free nanoscale nonlinear goniometry.

Rivista/Giornale:  ACS PHOTONICS
Volume n.:  5 (11)      Pagine da: 4386  a: 4392
DOI: 10.1021/acsphotonics.8b00810

   *Citazioni: 1
data tratti da "WEB OF SCIENCE" (marchio registrato di Thomson Reuters) ed aggiornati a:  12/05/2019

Riferimenti visionabili in IsiWeb of Knowledge: (solo per sottoscrittori)
Per visualizzare la scheda dell'articolo su IsiWeb: Clicca qui
Per visualizzare la scheda delle Citazioni dell'articolo su IsiWeb: Clicca qui

INO © Istituto Nazionale di Ottica - Largo Fermi 6, 50125 Firenze | Tel. 05523081 Fax 0552337755 - P.IVA 02118311006     P.E.C.    Info